Pure Sine Wave
SCOTT POWER LONG BACKUP PURE SINE WAVE UPS
Scott Power Long Backup Sine Wave UPS is the latest in the world of power backup systems. These UPSs are packed with user-friendly features and are symbols of convenience and comfort. These UPSs require very little maintenance and provides powerful performance with all-round protection.
FEATURES
|
|
LOAD CHART
66
RATING |
600VA |
800VA |
1500VA |
||||||
OPTIONS |
Option 1 |
Option 2 |
Option 3 |
Option 1 |
Option 2 |
Option 3 |
Option 1 |
Option 2 |
Option 3 |
FAN |
4 | 3 | 1 | 4 | 3 | 2 | 10 | 9 | 5 |
TUBE LIGHT |
3 | 3 | 1 | 5 | 5 | 2 | 9 | 9 | 8 |
COMPUTER |
x | x | 1 | x | x | 1 | x | x | 1 |
TELEVISION |
x | 1 | x | x | 1 | x | x | 1 | x |
TECHNICAL SPECIFICATIONS*
RATING |
600VA |
800VA |
1500VA |
|
INPUT |
Regulated UPS Mode |
|||
Under Voltage |
180+/-5V |
|||
Under Voltage Restoration | 185+/- 5V | |||
Over Voltage | 260+/-5V | |||
Over Voltage Restoration | 255+/-5V | |||
Unregulated UPS Mode |
||||
Under Voltage |
100+/-10V |
|||
Under Voltage Restoration |
115+/-10V |
|||
Over Voltage |
285+/-10V |
|||
Over Voltage Restoration |
270+/-10V |
|||
OUTPUT |
Maximum Power |
600VA |
800VA |
1500VA |
Voltage (UPS Mode) |
230V Nominal |
|||
Voltage (Mains Mode) |
Same as Input |
|||
Frequency (UPS Mode) |
50 Hz.+/- 2% |
|||
Frequency (Mains Mode) |
Same as Input (45-55 Hz.) |
|||
Overload |
>110% |
|||
Transfer Time (typical a.s) |
10 ms. |
|||
BATTERY |
Type |
120 AH – 150 AH Lead Acid Type |
||
Number |
1 |
2 |
||
Typical Recharge Time |
10 – 12 Hrs. |
|||
Protection |
LOW BATTERY, REVERSE POLARITY |
|||
LED DISPLAY |
||||
UPS On |
On |
|||
Low Battery Pre-Alarm |
Lo (UPS On) |
|||
Battery Low |
Lo |
|||
Mains On |
AC |
|||
Zip Charge |
CH |
|||
Overload |
OL (Steady) |
|||
No Load |
nL |
|||
Over Temperature |
th |
|||
Short Circuit under Battery Mode |
OL (Blinking) |
|||
MCB Trip or Short Circuit under Mains Mode |
bt |
|||
ALARMS |
Low Battery Pre-Alarm |
Beeping every 10 Seconds |
||
Low Battery |
Continuously Beeping for 10 Seconds |
|||
Overload |
Continuously Beeping for 10 Seconds |
|||
No Load Shut Down |
Continuously Beeping for 10 Seconds |
|||
Short Circuit |
Continuously Beeping for 10 Seconds |
|||
ENVIRONMENTAL |
Operating Temperature |
0-40oC (32-104oF) |
||
Storage Temperature |
0-40oC (32-104oF) |
|||
Humidity |
0-95% RH non-condensing |
SCOTT POWER UPS
Scott Power UPS comes from state-of-art facility. This UPS is specially designed for trouble free performance year after year. Scott Power UPS is continuously upgraded and enhanced with new and attractive features.
FEATURES
|
|
LOAD CHART
RATING |
3KVA |
|
OPTIONS |
Option 1 |
Option 2 |
FAN |
7 | 18 |
TUBE LIGHT |
7 | 18 |
TELEVISION |
1 | 1 |
AC 0.75 TON |
1 | x |
TECHNICAL SPECIFICATIONS*
RATING |
3 KVA |
|
INPUT AC RANGE |
Regulated UPS Mode |
|
Under Voltage |
100+/-5V |
|
Under Voltage Restoration | 185+/- 5V | |
Over Voltage | 260+/-5V | |
Over Voltage Restoration | 255+/-5V | |
Unregulated UPS Mode |
||
Under Voltage |
100+/-10V |
|
Under Voltage Restoration |
115+/-10V |
|
Over Voltage |
285+/-10V |
|
Over Voltage Restoration |
270+/-10V |
|
OUTPUT |
Maximum Power |
3 KVA |
Voltage (UPS Mode) |
230V Nominal |
|
Voltage (Mains Mode) |
Same as Input |
|
Frequency (UPS Mode) |
50 Hz.+/- 2% |
|
Frequency (Mains Mode) |
Same as Input (45-55 Hz.) |
|
Overload |
>110% |
|
BATTERY |
Type |
120 AH – 150 AH Lead Acid Type |
Number |
4 |
|
Typical Recharge Time |
10 – 12 Hrs. |
|
Protection |
LOW BATTERY, REVERSE POLARITY |
|
DISPLAY |
||
UPS On |
On |
|
Battery Low |
Lo |
|
Mains On |
AC |
|
Zip Charge |
CH |
|
Battery Charged |
99% |
|
Overload |
OL (Steady) |
|
No Load |
nL |
|
Over Temperature |
th |
|
Short Circuit under Battery Mode |
OL (Blinking) |
|
MCB Trip or Short Circuit under Mains Mode |
bt |
|
ALARMS |
Low Battery Pre-Alarm |
One Beep every 10 Seconds |
Low Battery |
Continuous Beeping |
|
Overload |
Continuous Beeping |
|
No Load Shut Down |
Continuous Beeping |
|
ENVIRONMENTAL |
Operating Temperature |
0-40oC (32-104oF) |
Storage Temperature |
0-40oC (32-104oF) |
|
Humidity |
0-95% RH non-condensing |
SCOTT POWER HIGHER KVA UPSScott Power Higher KVA UPS can run all home applications and other applications. These UPSs are designed to provide convenience, comfort and safe power for smooth running of all home applications and other applications.FEATURES
|
|
HOUSEHOLD APPLICATIONSAir Conditioner, Refrigerator, Microwave, LCD Projector, Plasma Television, Cooler, Water Pump, Washing MachineOTHER APPLICATIONSPetrol Pumps, Deep Freezers, Lifts, Small Offices, Nursing Homes, Data Centers, BPOs’ etc.LOAD CHART
RATING |
5KVA |
6KVA |
10KVA |
|||||
OPTIONS |
Option 1 |
Option 2 |
Option 3 |
Option 1 |
Option 2 |
Option 1 |
Option 2 |
Option 3 |
FAN |
12 | 10 | 5 | 13 | 17 | 12 | 10 | 12 |
TUBE LIGHT |
14 | 14 | 7 | 13 | 17 | 15 | 12 | 13 |
TELEVISION |
x | x | 2 | 1 | 2 | 2 | 2 | 2 |
AC 1.5 TON |
1 | x | x | 1 | x | 2 | x | 1 |
AC 2 TON |
x | 1 | 1 | x | x | x | 1 | x |
MICRO WAVE |
x | x | 1 | x | 1 | x | 1 | 1 |
TECHNICAL SPECIFICATIONS*
RATING |
5 KVA |
6 KVA |
10 KVA |
|||
INPUT AC RANGE |
Regulated UPS Mode |
|||||
Under Voltage |
180 + 5V |
|||||
Under Voltage Restoration | 185 + 5V | |||||
Over Voltage | 260 + 5V | |||||
Over Voltage Restoration | 255 + 5V | |||||
Unregulated UPS Mode |
||||||
Under Voltage |
140 + 5V |
|||||
Under Voltage Restoration |
150 + 5V |
|||||
Over Voltage |
280 + 5V |
|||||
Over Voltage Restoration |
270 + 5V |
|||||
OUTPUT ON UPS MODE |
Maximum Power |
5 KVA |
6 KVA |
10 KVA |
||
Voltage (UPS Mode) |
SINE WAVE 230 V (Nominal) |
|||||
Voltage (Mains Mode) |
Same as Input |
|||||
Frequency (UPS Mode) |
50 Hz. + 0.5% |
50 Hz. + 1% |
||||
Frequency (Mains Mode) |
Same as Input (45-55 Hz.) |
|||||
Overload |
>110% |
|||||
BATTERY |
Type |
120 AH – 150 AH Lead Acid Type |
||||
Number |
96V |
120V |
180V |
|||
Typical Recharge Time |
8 |
10 |
15 |
|||
Protection |
LOW BATTERY, REVERSE POLARITY |
|||||
LED DISPLAY |
||||||
Input Under Voltage |
MAIN LOW |
|||||
Input Over Voltage |
MAIN HI |
|||||
Low Battery Pre-Alarm |
CAUTION LOW BATTERY |
|||||
Battery Low |
TRIP BATTERY LOW |
|||||
Overload |
TRIP OVERLOAD |
|||||
Short Circuit in UPS Mode |
SHORT CIRCUIT |
|||||
Short Circuit in Mains Mode |
INPUT MCB TRIP |
|||||
Input MCB Trip |
INPUT MCB TRIP |
|||||
Over Temperature |
THERMAL SHUTDOWN |
|||||
ALARMS |
Low Battery Pre-Alarm |
One Beep every 10 Seconds |
||||
Low Battery |
Continuous |
|||||
Overload |
Continuous |
|||||
Short Circuit |
Five Beeps every 2 Seconds |
|||||
Mains MCB Trip |
One Beep every 12 Seconds |
|||||
Over Temperature |
Continuous |
|||||
ENVIRONMENTAL |
Operating Temperature |
0-40oC (32-104oF) |
||||
Storage Temperature |
0-40oC (32-104oF) |
|||||
Humidity |
0-95% RH non-condensing |
this is the